1200C 1-Zone Hydrogen Vertical Tube Furnace with PLC Ignition Controlled – PTV D40/300/14

PTV D40/440/12 is a vertical split tube furnace with vacuum-sealed OD40mm quartz tube, CE standard. It provides fast heating and quenching as well as the capability to heat samples under vacuum or atmosphere protection. Precise Shimaden microprocessor PID temperature controller programmable 32 segments with +/- 1ºC accuracy. Max. working temperature is 1200°C. Vertical tube furnaces are ideal for doing quenching tests for wire shape materials.

Send Email Chat Now
Product Overview

Hydrogen Tube Furnace is mainly designed to do quenching tests for wire shape materials under hydrogen atmosphere in lab and industrial. The hydrogen tube furnace adopts an PLC controlled Auto ignition device, it will detect and ingite the hydrogen gas at the gas outlet, chamber can be adopt a 40, 60, 80, or 100mm OD alumina tube and a pair of stainless steel vacuum sealing flanges with needle valves & gauge allow heating samples under vacuum or gas flow conditions.

Main Features
  • Tmax 1400℃
  • Hydrogen vertical tube furnace
  • Non-split, single zone
  • Sintering or Quenching tests for wire shape materials under hydrogen gas with PLC ignition control
  • Max vacuum level 10E-3 torr
  • Two sides heating ensure uniform temperature
  • Multiple atmosphere processes in a single cycle are available
  • Shimaden PID programmable 32 segments
  • SS304 vacuum sealing flanges with valves and pressure meter included
  • Split furnace door for easy installation of tube
  • CE certified, standard
Safety
  • Built-in ammeter and dual voltmeters for easy monitoring and troubleshooting.
  • Overheat protection shuts down the furnace if temperature is outside of acceptable range (refer to controller’s manual) or when the thermocouple is broken or malfunctions.
  • Power failure protection resumes furnace operation right after the point of failure when power is reestablished.
  • Microprocessor based self-tuning PID control provides optimum thermal process with minimal overshoot
Product Illustration


vertical tube furnace
Hydrogen gas tube furnace

Hydrogen gas tube furnace with PLC controlled ignition device

Technical Specifications
Model No.PTV D40/300/14
Heating zoneHeating length: 300mm /12″
Uniform temp zone: 140mm
Temperature uniformity +/- 5C
Power supply2.5KW
AC208-240V, 50/60Hz, single phase
Working temperatureTmax 1200°C (2192°F)
Continuously 1100°C (2012°F)
Temperature controllerShimaden PID controller
Auto-tune function
Programmable 32 segments
Temperature accuracy +/- 1°C
Heating rate≤25°C / min
ThermocoupleS type
Equip two pcs, dual protection
Furnace tubeMaterial: Alumina tube
Size:OD40, length 700mm
Atmosphere performanceH2, Ar, N2 etc
Vacuum flangesSS304 sealing flanges
Multiple gas inlets and outlets
Vacuum levelMax 10E-3 torr with molecular pump
Chamber liningMitsubishi Raw Material high alumina 1600# fiber board
Electronic componentsSchneider maker air switch, AC contactor, SSR Relay etc.
Heating elementSiC heater
Shipping infoWeight: 75 kgs
W890xL540xH1190mm
ComplianceCE, ISO
WarrantyOne-year limited warranty with lifetime support
Application Notes
  • Don’t fill any explosive gasses such as Hydrogen or Methane into the furnace tube without necessary safety controls and supervision.
  • Vertical Tube furnace with quartz tubes are designed for use under vacuum and low pressure < 0.2 bars / 3 psi / 0.02 MPa.
  • Small cracks may appear on the surface of the refractory ceramics over extended use. This is a normal occurrence and the cracks may be repaired with alumina coating
Size Comparison
Item namePTV D25/200/14PTV D60/300/14PTV D100/300/14
Heating length200mm300mm300mm
Tube sizeOD25xL700mmOD60xL1000mmOD100xL800mm
Power1.5 KW2.8 KW3.0 KW
Furnace dimensions (LxWxH)830x450x1620mm850x470x1620mm870x490x1620mm
Weight60 KGS95 KGS102 KGS

Enquiry Now